Impact Strength and Dimensional Accuracy of Heat-Cure Denture Base Resin Reinforced With ZrO2 Nanoparticles: An In Vitro Study

Begum, S. Sajida and Ajay, R. and Devaki, V and Divya, Krishnamoorthi and Balu, K. and Kumar, P. Arun (2019) Impact Strength and Dimensional Accuracy of Heat-Cure Denture Base Resin Reinforced With ZrO2 Nanoparticles: An In Vitro Study. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 11.0. S365-S370. ISSN 0975-7406

Full text not available from this repository.

Abstract

Background: Polymerization shrinkage and fracture are the two common trouble shoots with denture base resins. Polymerization shrinkage affects the dimensional accuracy and fit of the prosthesis. The effect of zirconia (ZrO2) nanoparticles on polymerization shrinkage is not documented yet. Purpose: The aim and objective of this study were to evaluate the impact strength and dimensional accuracy of heat-cured poly methyl methacrylate (PMMA) on reinforcement with ZrO2 nanoparticles. Materials and Methods: Conventional heat-cure denture base resin (control) and the polymer reinforced with 3, 5, and 7 wt% of ZrO2 nanoparticles were prepared and used in this study. Forty bar-shaped specimens were prepared and tested for impact strength using Charpy's type impact tester. Forty denture bases were fabricated and checked for dimensional accuracy by measuring the distance between the denture base and the cast in two different sections using the travelling microscope. Results: The impact strength decreased with increased concentration of ZrO2 and found to be least at 7 wt% concentration (2.01 +/- 0.26 J/mm(2)). The distance between the denture base and the cast significantly decreased both in the posterior palatal seal region (0.060 +/- 0.007 cm) and mid-palatine section region (0.057 +/- 0.006 cm) with ZrO2 nanoparticles reinforcement and was found to be least at 7 wt% concentration. Conclusion: Reinforcement of heat-cured PMMA with ZrO2 nanoparticles significantly increased the dimensional accuracy and decreased the impact strength.

Item Type: Article
Uncontrolled Keywords: Dimensional accuracy, impact strength, PMMA, travelling microscope, ZrO, nanoparticles
Subjects: Pharmacology, Toxicology and Pharmaceutics > Pharmacology & Pharmacy
Divisions: Dentistry > Vinayaka Mission‘s Sankarachariyar Dental College, Salem > Prosthodontics and Crown & Bridge
Dentistry > Vinayaka Mission‘s Sankarachariyar Dental College, Salem > Prosthodontics
Depositing User: Unnamed user with email techsupport@mosys.org
Last Modified: 06 Feb 2026 06:57
URI: https://ir.vmrfdu.edu.in/id/eprint/6168

Actions (login required)

View Item
View Item